This action checks recorded video from a specific camera or group of cameras for the specified period. 

To configure this action, do as follows:

  1. Configure the conditions to start a macro (see Configuring filters for event-driven macros).
  2. Select a camera or a group of cameras to check if there is a record in the archive (1).

    Attention!

    If the start of the macro was triggered by the activation of input or output (see Configuring filters for event-driven macros) that is not connected to any camera, you need to select a specific camera here. If you select a group of cameras or a camera that triggered the command, the action will not start.

  3. Select an archive where you want to check if recorded video is available (2). If you leave the field empty, all recorded video in this camera archives will be checked.
  4. Specify the depth of check (3). The check time period covers: [the time of the action start - (minus) the depth of the check; start time of the action].
  5. Select an action if the archive record for the specified period is found (4).
  6. Select an action if the archive records for the specified period are not found (5).

Note

If E-mail is selected as a reaction, then the target cameras will be indicated in the message (if a group of cameras was selected) for which there are no entries in the archive for the specified period.

You can also use two special purpose templates in the message:

  • {failureRecordCheck}failed check of a record in an archive (format: Server Name|Camera Name|Archive Name);
  • {successRecordCheck}successful check of a record in an archive (format: Server Name|Camera Name|Archive Name).

Attention! For the correct execution of the macro, synchronize the time across all Servers within the Domain.