Previous page Update  Updating Drivers Pack Next page

You can run C-Werk installation in quiet mode (unattended setup with no user intervention).

Note

During installation you may have to reboot the system. After rebooting the installation will continue automatically.

When Redist.exe process ends and not listed in Windows Task Manager, the installation is complete.

 This mode of installation can be configured by adding command-line options to setup.exe.  See the command-line options in the table.

Command-line option

                        Description

/? or /help

Open  the Help window

/x or /uninstall

Remove C-Werk and save the configuration

/x/removeall

Remove C-Werk and delete the configuration

/r or /repair

Repair C-Werk

/qn or /quiet

Silent install

/norestart

Disable automatic reboot of the system during installation

/debug

Log installation

/noOSCheck 

Skip OS compatibility check

/LANG=”ru”

Select installation language

ru - Russian

en - English

/INSTALLTYPE="ServerClient"

Installation options:

ServerClient - Server and Client (default)

Client

/ADD="[]"

Hers is the list of components to install or remove (if you remove/uninstall software) See the possible values in the table below.

/REMOVE="[]"

Hers is the list of components NOT to install or remove (if you remove/uninstall software) See the possible values in the table below.

/dpcmd="INSTALL_BOSCH_VIDEOSDK=\"no\""

Bosch VideoSDK driver Installation (see notes) 

no - do not install 

yes - install
/CMD="[commands]"

Basic installation options and values. Commands are [option] = \ "[value] \" or [option] = [value] '. See available installation options in the table below.

Attention!

Occasionally, when installing the Bosch VideoSDK driver,  the CLI  window opens. To continue with installation, close this window.

/ADD и /REMOVE values:

x86

x64

BaseProductBaseProduct
IPDriverPack_x86IPDriverPack_x86
Guardant_x86Guardant_amd64
PostgresPostgres
dotnetfx35_x86dotnetfx35_x86
Redist2005_x86Redist2005_x86
Redist2010_x86Redist2010_x86
DetectorPackDetectorPack

 

Installation options:

Installation options

Description

QUICKLAUNCH_SHORTCUT='1'

Create shortcut:

1 - Yes (default)

0- No

DESKTOP_SHORTCUT='1'

Copy shortcut to desktop:

1 - Yes (default)

0- No

INSTALLDIR='[%ProgramFiles%\Grundig\C-Werk]'

C-Werk installation folder

NGP_IFACE_WHITELIST="0.0.0.0/0"

Network interfaces The default value is "0.0.0.0/0"  (all available network interfaces)

Format of network interfaces: "IP-address1 / number of unit bits in the mask, IP-address2 /number of unit bits in the mask"

NGP_ALT_ADDR="0.0.0.0"

Setting the outside local address for a Server behind the NAT). 

Format of network interfaces: "IP Address1 or DNS-name1, IP address2 or DNS Name2"
PORT_RANGE_START="49999"

The initial value of the port range for Server. 49999 - default.

PORT_RANGE_COUNT="100"

Number of ports in use. The minimum number is 20. 100 - default.

Options for Server and Client installation

PATH_TO_DATABASE='[INSTALLDIR]Metadata'

Path to object tracking DB.

FBUSER_TYPE='DEFAULT'

User account for file explorer:

DEFAULT  - Create a new account; the default name selected will be C-Werk File Browser.

SYSTEM - Select an account  from the Local System.

SPECIFY - Create a new account; choose the user name and password.

FBUSER_NAME='[C-Werk File Browser]'

Setting a user name and password for an account in file explorer.

When you choose  SPECIFY of the  FBUSER_TYPE parameter

FBUSER_PSW='[C-Werk2.0.0]'
CONFIG_PATH='[CommonAppDataDirectory]'

Path to configurations files and folders

DOMAIN_NAME_TYPE = '[NewDomain]'

Select C-Werk-domain:

NewDomain - create new C-Werk Domain (deafault);

WithoutDomain - do NOT add Server to C-Werk Domain

TheSameDomain - use existing C-Werk-domain

WHATDBUSE = '[EXIST]'

EXIST - Use existing log  DB (default)

NEWDB - Create new DB

WHATVMDADBUSE = '[EXIST]'

EXIST - Use existing object tracking DB (default)

NEWDB - Create new DB

The command for silent installation of C-Werk may look like:

setup.exe /quiet /norestart /debug /INSTALLTYPE="ServerClient" /REMOVE="Guardant_x86" /CMD="CREATE_QUICKLAUNCH_SHORTCUT=\"0\" PORT_RANGE_COUNT=\"50\" DOMAIN_NAME_TYPE=\"WithoutDomain\""

This will launch installation  with the following options:

  1. quite mode (/quiet);
  2. no reboot (/norestart);
  3. log installation to file (/ debug);
  4. Server and Client (/ INSTALLTYPE = "ServerClient");
  5. No  Guardant drivers (/ REMOVE = "Guardant_x86");
  6. And with the following properties (/ CMD =):
    1. no shortcut (="CREATE_QUICKLAUNCH_SHORTCUT=\"0\");
    2. 50 ports for Server (PORT_RANGE_COUNT="50");
    3. Server NOT added to C-Werk-domain (DOMAIN_NAME_TYPE = '[WithoutDomain]').
  • No labels