To configure the Visitors counter detection tool, do the following:
Click the button and specify the size of a human (4). You can do this by dragging the anchor points of the rectangular area. You can also specify the size of a human manually by entering into the Human size field (9) the area of the rectangle around a human as a percentage of the frame area. Consider that to calculate the size, the size of the compressed frame is taken into account (7) and not the original size of the video stream. The value should be in the range [1; 75].
Attention!
When specifying the size of a human, consider the Requirements for the person size in the frame.
By default, during analysis the frame is compressed to the specified size (7, the default size is 640 pixels on the larger side). The value should be in the range [640; 10000]. The following algorithm is used:
If the resulting resolution is still greater than the specified one, then it is divided in half until it becomes less.
Note
For example, the original video image resolution is 2048*1536, the specified value is 1000. In this case, the original resolution will be halved 2 times (512*384), because after the first division, the value on the larger side of the frame will be greater than the specified value (1024 > 1000). If detection is performed on a higher resolution stream and detection errors occur, it is recommended to reduce the compression.
By default, the detection tool generates the Camera. Visitor access in the direction of "Entrance" and Camera. Visitor access in the direction of "Exit" events. If you also want to count visitors at the facility, and it is necessary to trigger an alarm when the threshold value is exceeded, do the following:
Select Yes for the People indoor counter parameter (11).
Configuration of the Visitors counter detection tool is now complete.