Documentation for C-Werk 2.0.

Previous page Configuring C-Werk instead of the standard Windows OS shell  Configuring automatic exiting and locking of the Client Next page

It is possible for the Client to automatically connect to Servers on different Domains − Cross-System Client.

For this to take place, the following conditions must be true:

  • Proffesional or Universe license has been activated on each Server to which the Client is connected;
  • connection to all Servers made via with the same user name/password combination on each Domain;
  • Server names and IP addresses are unique.

Configuration of automatic connection to Servers on different Domains is performed as follows:

  1. Go to Settings  Options  Automatic connection (1-2).

  2. Configuring the protocol used by Clients to connect to the Server allows prioritizing reliability or speed of data transmission (3).The connection protocol is set individually for each Server in an Domain. All Clients connected to the Server will receive video streams over the selected protocol.

    Descriptions and recommendations for selecting a protocol are given in the table.

    ProtocolDescription
    TCPThis protocol is more reliable but bandwidth-intensive. Recommended for Servers with small numbers of cameras.
    UDP unicast

    UDP is typically faster but less reliable for data transmission. Unicast involves data transmission to a single recipient.

    This protocol is best for Servers with many cameras connected to a single Client.

    UDP multicast

    Multicast refers to data transmission to a group of recipients. This protocol is designed for Servers with many cameras connected to multiple Clients.

    Important! This protocol has to be supported by all network components, in particular, switches. 

  3. Type the user name and password needed for logging in to each Domain (4).
  4. Indicate the Servers to connect to. For each Server, perform the following steps: 
    1. select the Server in the list (5);
    2. indicate the port for connecting to the Server (6).

      Note

      If the Port field is left blank, the standard port (20111) will be used for connecting.

    3. Click the Add button (7).

      Note

      It is possible to connect to only one Server on an Domain. So when a Server is added to the list, all other Servers on the Domain become unavailable for selection.

      Note

      To remove a Server from the list, click the  button.

  5. After all Servers have been added to the list, select the main Domain.
    When connecting, the Client will use the parameters (maps, layouts, user rights) of the main Domain. 
    To select a main Domain, select the check box in the relevant column of a Server that is on the Domain (8).
  6. Click the Apply button.

Click Export (9) to save the automatic Server connection and Preferred Servers (see Selecting Preferred Servers) configuration to the JSON file.

To load the preset configuration to other Clients, do the following:

  1. Click Import (10).
  2. Click Apply.

To change a port on an added Server, do the following:

  1. Select this Server again from the list (11). 
  2. Enter a new port (12).
  3. Click Change (13).

Autoconnection to Servers on different C-Werk time C-Werk is started, connection to the selected Servers with the specified user credentials will occur automatically.

If the Client is connected to several Servers, the Server settings are reproduced for each Server (see Server settings).