Documentation for C-Werk 2.0.

Previous page Appendix 3. Assigning of the domain takes place when the C-Werk server is installed  Appendix 5. Using CH VM-Desktop USB multifunction controllers with C-Werk Next page

On the page:


To ensure the correct operation of C-Werk, it is recommended to configure the antivirus as follows:

  1. Add the following processes to the exclusion list:

    1. consul.exe;
    2. nomad.exe;
    3. apphost.exe;
    4. postgres.exe.
  2. Add the following folders to the exclusion list:
    1. C:\ProgramData\Grundig\C-Werk;
    2. C:\Program Files\Grundig\C-Werk;
    3. C:\Program Files\Common Files\Grundig;
    4. Postgres and metadata folders if they were changed during installation.
  3. Add the following ports to the exclusion list:
    1. 20109-20210;
    2. 4000 (only for the Failover server and client installation type);
    3. 4646-4648 (only for the Failover server and client installation type);
    4. 8300-8302 (only for the Failover server and client installation type);
    5. 8500 (only for the Failover server and client installation type);
    6. 8600 (only for the Failover server and client installation type).

Depending on the antivirus software that you use, when you install, start, and use C-Werk, your antivirus software may ask for permission for the software components to perform Internet access.

It is recommended that you allow these components to do so for proper functioning of the application.

Recommendations for the specific antivirus programs are given below.

ESET NOD32

If you use ESET NOD32 antivirus, it is strongly recommended to either disable the Web Access Protection service, or add the IP addresses of the IP cameras to the list of exclusions for antivirus scanning.

See also Possible Errors During Start-Up.

ESET NOD32 Internet Security

If you use ESET NOD32 Internet Security antivirus, if the SSL/TLS protocol filtering is enabled, it is strongly recommended to either add the certificate file to the list of known certificates, or add the C-Werk Security antivirus, select automatic mode with exclusions for Firewall and add the remote Servers to the exclusions by creating network rules (for help with creating these rules, refer to the official user guide for the antivirus software).

AVG

When you install C-Werk, allow the NetHost.exe and ngpsh.exe processes to run.

If you use AVG antivirus and a configuration with many video cameras, it is strongly recommended to add the IP addresses of the IP cameras to the list of exclusions. Otherwise, the avgsa.exe process may severely slow down the CPU.
This action can be performed only on the paid version of AVG.

DrWeb

If you use DrWeb antivirus, do the following before installing C-Werk:

  1. Disable the automatic start of the DrWeb firewall.
  2. In the proactive protection settings, select the option to use custom settings and enable the following options:
    1. Allow low-level disk access
    2. Allow system services
    3. Allow loading drivers
    4. Allow User drivers
    5. Allow Winlogon shell parameters
  3. In the SpiDer Gate settings, add the apphost.exe and C-Werk.exe processes to the list of exclusions for scanning of incoming traffic. If possible, it is recommended to disable scanning of incoming and outgoing traffic.