General description of the UNIVIEW KB-1100 PTZ control device

A schematic representation of the UNIVIEW KB-1100 PTZ control device is shown in the figure below.

The following physical controls are available on the device:

Joystick is a rotary control moving along three axes:

  • Pan axis (panning: left or right deviation).
  • Tilt axis (tilt: up or down deviation).
  • Zoom axis (scaling: clockwise or counterclockwise deviation).

Acceleration along each of the three axes depends on the degree of deviation from the center. The movement is carried out until release. When released, the control returns to its original position.

Jog-Wheel (not integrated into the C-Werk software package!) is a rotary control rotating only around its axis. When released, the control returns to its original position. In the illustration it is located at the bottom left (outer ring).

Shuttle is a rotary control rotating only around its axis. Allows the intermittent movement in one of two directions. It has no initial position; when released, it remains in place. In the illustration it is located at the bottom left (inner ring).

Button is a push control element that can represent two states. Allows the call of one of two functions (the function for pressing and the function for releasing). When released, it returns to its original position (“not pressed” state).

Of all the push-button controls of the remote control, the following blocks are integrated:

  • A block of playback control keys (6 keys on the left: the record button is triggered after pressing a button on the joystick).
  • Block of keys for control of focus, zoom, aperture and PTZ presets (8 keys).

The following keys to manipulate the device interface are also available (not related to C-Werk):

  • Pressing the button on the remote control joystick (OK) (equivalent to pressing the ENTER key).
  • Cancel the action / return one step back in the remote control menu (equivalent to pressing the ESC key).
  • Numbers / letters are entered from the numeric keyboard, the mode (upper/lower register, digits) is switched by the SHIFT key.
  • Moving through the menu items and within the fields is carried out by deviating the remote control vertically / horizontally.

Configuring a remote control before adding it to C-Werk

Configure the network PTZ 4-dimensional Joystick Remote Control from Uniview (KB-1100) before you create the appropriate object in the C-Werk VMS. Proceed as follows:

  1. Switch on the control device.
  2. Enter username and password in the device display. The default credentials are as follows:
    1. Login: admin.
    2. Password: 123456.
  3. Configure the device network configuration. To do this, in the Local Cfg -> Net Cfg menu, set the following settings:
    1. IP address.
    2. Mask.
    3. Gateway.
  4. Add the C-Werk Server to the internal configuration of this CCTV joystick keyboard. To do this, in the Dev Manage -> Manual Cfg -> Add Dev menu, set the following settings:

    1. ID – enter any number (range: 1-240, the number must not coincide with the ID of the remote control or other already added device).
    2. Name – enter a string (1-8 characters).
    3. DType – select VM (VideoManagementSystem, i.e. C-Werk).
    4. LType – select NetWork (the device is integrated for connecting to C-Werk via the network).
    5. After selecting LType, press the button on the joystick and enter the IP address of the C-Werk VMS Server and the port used (the default port is 60000).

  5. Connect to the C-Werk VMS, added in the step above. To do this, enter the ID specified above in the FindDev -> Dev ID menu or select the found profile in the Dev Manage -> Search Dev menu.

  6. If the device is found, information about it will be displayed on the device display.
  7. Press on the ID field. This will onboard the remote control  in the C-Werk VMS.

Setting up the UNIVIEW KB-1100 control device is completed.

Configuring  UNIVIEW KB-1100 in C-Werk

Configure the UNIVIEW KB-1100 PTZ joystick control as follows:

  1. Go to IP Device Discovery Wizard (see Adding and removing IP devices).
  2. In the Vendor list select Uniview-joystick (1).
  3. In the IP address field, enter the IP address of the remote control (2).
  4. In the Port field, enter the port number, as set in step 4 of the remote control settings configuration (3).
  5. Click the .
  6. Enable the newly created IP Server and its Channel child object.

You have configured the UNIVIEW KB-1100 Joystick Remote Control and CCTV keyboard.