Documentation for C-Werk 2.0.

Previous page Immersion mode  Displaying device status Next page

Using the context menu of icons on the map, you can control outputs and logical objects (counters, macros), as well as control video cameras and configure their interface.

Commands for controlling and configuring video camera interface are given in the table below.

Command (context menu item)

Condition

Result after the command is performed

Arm

The camera is disarmed

Icon status:

Private Arm (see Arming and Disarming a Video Camera)

The camera is disarmed

Icon status:

Disarm

The camera is armed

Icon status:  

Show videoVideo image is not displayed

Video image display:

Hide videoVideo image is displayedVideo image is not displayed
Show layoutAdditional conditions are not requiredThe selected camera is displayed on the temporary layout. To display multiple selected cameras on the temporary layout, see Selecting Cameras for a Temporary Layout
CopyAdditional conditions are not requiredIf you right- or left-click on any cell of the layout, then the video from the copied video camera will be displayed in this cell. The copied camera will be displayed on the layout until you switch to another layout or restart the client

Commands for controlling outputs are given in the table below.

Command (context menu item)

Condition

Icon status after the command is performed

Turns the output on

Output in normal status

Disable output

Output is activated

 

Note

You cannot switch the status of the Output from the map if there are macros with the corresponding action running in the system (see Switch output).

Commands for controlling macros are listed in the table below.

Command (context menu item)

Condition

Command description

Start

Event-driven macro

Running the macro

Enable

Disabled cyclic macro

Enabling the macro

Disable

Enabled cyclic macro

Disabling the macro

On top of that, you can manage macros with the Start button and the Enable check box.

Commands for controlling counters are listed in the table below.

Command (context menu item)

Condition

Command description

Stop

The counter is running

Stopping the counter. If the counter is on pause, its value does not change

Start

The counter is stopped

Starting the counter. If the counter is running, its value changes as specified

Clear

Any state

Resets the counter value to 0