Documentation for C-Werk 2.0.

Previous page Settings specific to Stop in area detection  Setting up Scene Analytics detection tools based on Neurotracker Next page

To configure the Move from area to area detection tool, do the following:

  1. Set the general parameters (see Setting general parameters of Tracker-based Scene Analytics detection tools).
  2. Set two areas in the preview window. The tool is triggered if any object moves from one area to the other in the specified direction.
    By default, the areas are located on the right side and the left side of the video image. The anchor points of each area are connected by a two-color dotted line. To reshape the area, drag its anchor points . To move the entire area, left click and drag its border. To add the anchor points, click .
  3. In the preview window, set the directions of the object movement. The direction of movement between the areas is indicated by a dotted arrow. To change the direction of movement, click  on the direction arrow. The available directions are:
    1. Left.
    2. Right.
    3. Both directions.
  4. Click the Apply button.

The Move from area to area detection tool is configured.

  • No labels