Documentation for C-Werk 2.0.

Previous page Settings specific to Multiple objects  Settings specific to Move from area to area detection tool Next page

The detection tool will trigger if an object stops and remains idle for a specified time period.

Note

The object doesn't have to be completely idle, minor jitter is permitted.

To set a specified time period, you must perform the following steps:

  1. In the Detection Tools list, highlight a Stop in area object (1).
  2. Set the idle period duration for triggering the tool (2). This value should fall into the range of [0, 3600].

    Attention!

    Set this parameter to a value lower than the Time of object in DB in Object tracker settings (see Setting general parameters of Tracker-based Scene Analytics detection tools).

    Attention!

    If a detection tools runs on VMD metadata, the Stop in area duration should be set to 0. Otherwise, the detection tools will not work.

  3. Click the Apply button.