Previous page Configuring the queue detection tool  Configuring Built-In Detectors Next page

Attention!

The visitor counter is better fit for producing average figures than exact values.

Attention!

We cannot guarantee correct operation of the visitors counter with fish-eye video cameras.

To configure the visitors counter:

  1. By default, the frame is compressed to 1920 pixels on the longer side. To avoid detection errors on streams with a higher resolution, it is recommended that compression be reduced.

  2. In the Preview window, set the detection area. It is divided to two sectors, #1 and #2. When an object moves from #2 to #1, the system treats it as entry; alternatively, #1 to #2 is treated as exit.
    To configure the sectors, you can drag them by corners  or sides. 

    To swap sectors, just click inside one of them.

    Note

    To show / hide sectors in the Preview window, click the button.

  3. Click  and specify the approximate size of a human. You can do so by dragging the corners of the rectangular area. 
  4. Click Apply.

Configuration of the visitors counter is now complete. When the detector is triggered, the following events are generated: Camera. Visitor access in the direction of "Entrance" and  Camera. Visitor access in the direction of "Exit".

To enable the visitors counter, we advise you to set the Statistics board to the corresponding event (see Configuring a Statistics Board).

  • No labels