To configure the Queue detection tool, do the following:
Set the event transmission interval in seconds for sending the data to the AxxonData report subsystem (see Queue length report), if the queue length exceeds the set limit (3). If 0 value is selected, no events will be transmitted.
Analyzed framed are scaled down to a specified resolution (5, 1920 pixels on the longer side). This is how it works:
If the longer side of the source image exceeds the value specified in the Frame size change field, it is divided by two.
If the resulting resolution falls below the specified value, it is used further.
If the resulting resolution still exceeds the specified limit, it is divided by two, etc.
Note
For example, the source image resolution is 2048*1536, and the specified value is set to 1000.
In this case, the source resolution will be halved two times (512*384), as after the first division, the number of pixels on the longer side exceeds the limit (1024 > 1000).
Note
If detection is performed on a higher resolution stream and detection errors occur, it is recommended to reduce the compression.
Click the button and set the minimum size of a human (7). You can do so by dragging the anchor points of the rectangular area.
Note
It is recommended to set the minimum size of a human graphically. The number in the Human size field is a conventional value.
The Queue detection tool is now configured. When the detection tool is triggered, the following events are generated:
Camera. Detection "Queue detection" triggered, queue (min.: 10, max.: 10)
where min. and max. is estimated queue length.