Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

You can run Axxon Next C-Werk installation in quiet mode (unattended setup with no user intervention).

...

Command-line option

                        Description

/? or /help

Open  the Help window

/x or /uninstall

Remove Axxon Next C-Werk and save the configuration

/x/removeall

Remove Axxon Next C-Werk and delete the configuration

/r or /repair

Repair Axxon NextC-Werk

/qn or /quiet

Silent install

/norestart

Disable automatic reboot of the system during installation

/debug

Log installation

/noOSCheck 

Skip OS compatibility check

/LANG=”ru”

Select installation language

ru - Russian

en - English

/INSTALLTYPE="ServerClient"

Installation options:

ServerClient - Server and Client (default)

Client

/ADD="[]"

Hers is the list of components to install or remove (if you remove/uninstall software) See the possible values in the table below.

/REMOVE="[]"

Hers is the list of components NOT to install or remove (if you remove/uninstall software) See the possible values in the table below.

/dpcmd="INSTALL_BOSCH_VIDEOSDK=\"no\""

Bosch VideoSDK driver Installation (see notes) 

no - do not install 

yes - install
/CMD="[commands]"

Basic installation options and values. Commands are [option] = \ "[value] \" or [option] = [value] '. See available installation options in the table below.

...

Installation options

Description

QUICKLAUNCH_SHORTCUT='1'

Create shortcut:

1 - Yes (default)

0- No

DESKTOP_SHORTCUT='1'

Copy shortcut to desktop:

1 - Yes (default)

0- No

INSTALLDIR='[%ProgramFiles%\AxxonSoftGrundig\AxxonSmartC-Werk]'

Axxon Next C-Werk installation folder

NGP_IFACE_WHITELIST="0.0.0.0/0"

Network interfaces The default value is "0.0.0.0/0"  (all available network interfaces)

Format of network interfaces: "IP-address1 / number of unit bits in the mask, IP-address2 /number of unit bits in the mask"

NGP_ALT_ADDR="0.0.0.0"

Setting the outside local address for a Server behind the NAT). 

Format of network interfaces: "IP Address1 or DNS-name1, IP address2 or DNS Name2"
PORT_RANGE_START="49999"

The initial value of the port range for Server. 49999 - default.

PORT_RANGE_COUNT="100"

Number of ports in use. The minimum number is 20. 100 - default.

Options for Server and Client installation

PATH_TO_DATABASE='[INSTALLDIR]Metadata'

Path to object tracking DB.

FBUSER_TYPE='DEFAULT'

User account for file explorer:

DEFAULT  - Create a new account; the default name selected will be AxxonFileBrowserC-Werk File Browser.

SYSTEM - Select an account  from the Local System.

SPECIFY - Create a new account; choose the user name and password.

FBUSER_NAME='[AxxonFileBrowserC-Werk File Browser]'

Setting a user name and password for an account in file explorer.

When you choose  SPECIFY of the  FBUSER_TYPE parameter

FBUSER_PSW='[Axxon2C-Werk2.0.0]'
CONFIG_PATH='[CommonAppDataDirectory]'

Path to configurations files and folders

DOMAIN_NAME_TYPE = '[NewDomain]'

Select AxxonC-Werk-domain:

NewDomain - create new Axxon C-Werk Domain (deafault);

WithoutDomain - do NOT add Server to Axxon C-Werk Domain

TheSameDomain - use existing AxxonC-Werk-domain

WHATDBUSE = '[EXIST]'

EXIST - Use existing log  DB (default)

NEWDB - Create new DB

WHATVMDADBUSE = '[EXIST]'

EXIST - Use existing object tracking DB (default)

NEWDB - Create new DB

The command for silent installation of Axxon Next C-Werk may look like:

setup.exe /quiet /norestart /debug /INSTALLTYPE="ServerClient" /REMOVE="Guardant_x86" /CMD="CREATE_QUICKLAUNCH_SHORTCUT=\"0\" PORT_RANGE_COUNT=\"50\" DOMAIN_NAME_TYPE=\"WithoutDomain\""

...

  1. quite mode (/quiet);
  2. no reboot (/norestart);
  3. log installation to file (/ debug);
  4. Server and Client (/ INSTALLTYPE = "ServerClient");
  5. No  Guardant drivers (/ REMOVE = "Guardant_x86");
  6. And with the following properties (/ CMD =):
    1. no shortcut (="CREATE_QUICKLAUNCH_SHORTCUT=\"0\");
    2. 50 ports for Server (PORT_RANGE_COUNT="50");
    3. Server NOT added to AxxonC-Werk-domain (DOMAIN_NAME_TYPE = '[WithoutDomain]').