Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

You can set a number of specific parameters which affect triggering a face recognition macro:

  1. Age of the individual (requires activation of the Gender and Age parameter, see Configuring Face detection).
  2. Gender of the individual (requires activation of the Gender and Age parameter, see Configuring Face detection). Value: 1 = female, 2 = male.
  3. TemperatureValue: body temperature of the individual (requires the Face Detection and Temperature Control, see Face Detection and Temperature Control with Mobotix M16 TR cameras).

To set specific parameters, do the following:

  1. Select Faces: Specified triggering event as a launch condition.
  2. Click .
  3. Specify a required parameter value in the corresponding field (1). 

    Note
    titleAttention!

    The parameter is case-sensitive.


  4. In the Value (2) and Max value (3) fields, set the range of parameter values within which the macro will be triggered. 

    Info
    titleNote

    Examples. 

    If you set Age to [18, 100], the macro will be triggered only if the detection tool returns the age value of 18 or more.

    If you set Gender to [1, 1], the macro will be triggered only if the detection tool returns the individual's gender as female.

    If you set Gender to [2, 2], the macro will be triggered only if the detection tool returns the individual's gender as male.

    If you set TemperatureValue to [37, 100], the macro will be triggered only if the detection tool returns the temperature value of 37 or more.


  5. Add one or more actions into the macro (see Settings specific to actions).
  6. Click the Apply button.