Axxon Next C-Werk VMS supports automatic copying of the archive (video, audio, alarms) and camera events from local servers that are not in the same Axxon C-Werk domain with the centralized server

...

  1. Manually add the IP device to the configuration:
    1. selecting Interop in the Vendor field (1, see Adding and removing IP devices);
    2. enter the Server port from which the data will be sent (2).

  2. Enable The Embedded Storage object.
  3. Specify the address of the device in the following format (1):  <IP-address of local server>:<name of local server in Axxon C-Werk domain>:<ID of camera on server>.
  4. Specify the port of the local web-server (2, see Configuring the web server).
  5. Specify the user name and password (3). The user must have permissions to access the local server.
  6. If you want to display live video from the local server when it is available, select Yes in the appropriate field (4).
  7. Specify the maximum playback speed (5).
  8. Click the Apply button.
  9. Repeat the above steps for all the required cameras from all local servers.
  10. Configure automatic replication from the embedded storages of the added devices to the centralized server archive (see Configuring data replication).

    Note
    titleAttention!

    With a high network load, there may be gaps in the centralized server archive.

...