You can run Axxon Next C-Werk installation in quiet mode (unattended setup with no user intervention).
...
Command-line option | Description |
| /? or /help | Open the Help window |
| /x or /uninstall | Remove Axxon Next C-Werk and save the configuration |
| /x/removeall | Remove Axxon Next C-Werk and delete the configuration |
| /r or /repair | Repair Axxon NextC-Werk |
| /qn or /quiet | Silent install |
| /norestart | Disable automatic reboot of the system during installation |
| /debug | Log installation |
| /noOSCheck | Skip OS compatibility check |
| /LANG=”ru” | Select installation language ru - Russian en - English |
| /INSTALLTYPE="ServerClient" | Installation options: ServerClient - Server and Client (default) Client |
| /ADD="[]" | Hers is the list of components to install or remove (if you remove/uninstall software) See the possible values in the table below. |
| /REMOVE="[]" | Hers is the list of components NOT to install or remove (if you remove/uninstall software) See the possible values in the table below. |
| /dpcmd="INSTALL_BOSCH_VIDEOSDK=\"no\"" | Bosch VideoSDK driver Installation (see notes) no - do not install yes - install |
| /CMD="[commands]" | Basic installation options and values. Commands are [option] = \ "[value] \" or [option] = [value] '. See available installation options in the table below. |
...
Installation options | Description |
| QUICKLAUNCH_SHORTCUT='1' | Create shortcut: 1 - Yes (default) 0- No |
| DESKTOP_SHORTCUT='1' | Copy shortcut to desktop: 1 - Yes (default) 0- No |
| INSTALLDIR='[%ProgramFiles%\AxxonSoftGrundig\AxxonSmartC-Werk]' | Axxon Next C-Werk installation folder |
| NGP_IFACE_WHITELIST="0.0.0.0/0" | Network interfaces The default value is "0.0.0.0/0" (all available network interfaces) Format of network interfaces: "IP-address1 / number of unit bits in the mask, IP-address2 /number of unit bits in the mask" |
| NGP_ALT_ADDR="0.0.0.0" | Setting the outside local address for a Server behind the NAT). Format of network interfaces: "IP Address1 or DNS-name1, IP address2 or DNS Name2" |
| PORT_RANGE_START="49999" | The initial value of the port range for Server. 49999 - default. |
| PORT_RANGE_COUNT="100" | Number of ports in use. The minimum number is 20. 100 - default. |
Options for Server and Client installation | |
| PATH_TO_DATABASE='[INSTALLDIR]Metadata' | Path to object tracking DB. |
| FBUSER_TYPE='DEFAULT' | User account for file explorer: DEFAULT - Create a new account; the default name selected will be AxxonFileBrowserC-Werk File Browser. SYSTEM - Select an account from the Local System. SPECIFY - Create a new account; choose the user name and password. |
| FBUSER_NAME='[AxxonFileBrowserC-Werk File Browser]' | Setting a user name and password for an account in file explorer. When you choose SPECIFY of the FBUSER_TYPE parameter |
| FBUSER_PSW='[Axxon2C-Werk2.0.0]' | |
| CONFIG_PATH='[CommonAppDataDirectory]' | Path to configurations files and folders |
| DOMAIN_NAME_TYPE = '[NewDomain]' | Select AxxonC-Werk-domain: NewDomain - create new Axxon C-Werk Domain (deafault); WithoutDomain - do NOT add Server to Axxon C-Werk Domain TheSameDomain - use existing AxxonC-Werk-domain |
| WHATDBUSE = '[EXIST]' | EXIST - Use existing log DB (default) NEWDB - Create new DB |
| WHATVMDADBUSE = '[EXIST]' | EXIST - Use existing object tracking DB (default) NEWDB - Create new DB |
The command for silent installation of Axxon Next C-Werk may look like:
setup.exe /quiet /norestart /debug /INSTALLTYPE="ServerClient" /REMOVE="Guardant_x86" /CMD="CREATE_QUICKLAUNCH_SHORTCUT=\"0\" PORT_RANGE_COUNT=\"50\" DOMAIN_NAME_TYPE=\"WithoutDomain\""
...
- quite mode (/quiet);
- no reboot (/norestart);
- log installation to file (/ debug);
- Server and Client (/ INSTALLTYPE = "ServerClient");
- No Guardant drivers (/ REMOVE = "Guardant_x86");
- And with the following properties (/ CMD =):
- no shortcut (="CREATE_QUICKLAUNCH_SHORTCUT=\"0\");
- 50 ports for Server (PORT_RANGE_COUNT="50");