Set the interval between the processes frames in seconds (1). The value should be in the [1;30] range.
Info title Note The default values (5 frames and 10 seconds) indicate that the tool will analyze one frame every 10 seconds. When smoke (fire) is detected in 5 frames, the tool will trigger.
- Select the processor for the neural network — CPU, one of GPUs or a IntelNCS (2).
Select a neural network file (3). The The following standard neural networks for different processor types are located in C:\Program Files\Common Files\Video Management System\DetectorPack\NeuroSDK:
smoke_movidius.ann
Smoke detector / IntelNCS
smoke_openvino.ann
Smoke detector / CPU
smoke_original.ann
Smoke detector / GPU
fire_movidius.ann
Fire detector / IntelNCS
fire_openvino.ann
Fire detector / CPU
fire_original.ann
Fire detector / GPU
- Set the minimum number of frames with smoke (fire) for triggering the tool (4). The value should be in the [5;20] range.
- You can experiment with the sensitivity of the tool ( 4 5). The The value must be in the range [1; 99]. The preview window displays the sensitivity scale of the detection tool. It is color-coded as follows:
Green - smoke (fire) not detected.
Yellow - smoke (fire) detected, but not enough to trigger the tool.
Red - smoke (fire) detected.
If you increase the sensitivity value, you have more alerts (red scale).
In the preview window, you can set the detection zones with the help of anchor points much like privacy masks in Scene Analytics (see Setting general zones for scene analytics). By default, the entire FoV is a detection zone.
...