If necessary, set Yes for the Advanced logging for SDK parameter (1).
Note | ||
---|---|---|
| ||
Starting from DetectorPack 3.9.0, the Advanced logging for SDK parameter is absent. You can enable the advanced logging for SDK using the VL_SDK_VERBOSE_LOGGING=1 system variable (see Appendix 9. Creating system variable). |
In the Face rotation yaw to (°) field (7), set the maximum allowable angle of face rotation to the right or left. The value should be in the range [-90; 90].
In the Number of frames without detections field (10), enter the time in milliseconds in the range [1; 10000]. If there is no face detection in the selected area, the TrackEngine will continue to process the specified number of frames before the track is considered lost.
Info | ||
---|---|---|
| ||
TrackEngine does not perform face recognition. It tracks the position of one person's face in a sequence of frames, choosing the best frame and preparing the necessary data for external systems. TrackEngine is based on face detection and analysis methods provided by the FaceEngine library. |
Specify the Number of threads per recognition channel (11). The value should be in the range [1; 256].
...