Configuring the Hikvision DS-1200KI control device before adding it to C-Werk

Configure the Hikvision DS-1200KI PTZ control device as follows before creating the corresponding object in C-Werk:

  1. Set the control device address: Select System − Network in the device internal menu, then disable DHCP and set IP address and gateway.
  2. Set the C-Werk server IP address and port on the device. Open the device Web interface by entering the above set IP address in the web browser, then select Platform Access − Third-Party Platform.

    The Web interface is only available on https by default, so please use https prefix before the IP address.

  3. Set the 8. Private VMS mode in the device's internal interface.
  4. Transfer the PTZ control device to operating mode by one of the following actions:
    1. Select any monitor MON (monitor) [integer in the range 1-9999], any camera CAM (camera) [integer in the range 0-999999]; in this mode all keys will work, including the WIN (subwindow of video wall) and MULT (layout size) keys for the monitor and camera.
    2. Select any camera CAM (camera) [integer number in the range 1-999999 (number 0 is available only when setting the monitor)]; the WIN, MULT and CAM-G keys will not work in this mode.
    3. Select any monitor MON (monitor) [integer in the range 1-9999] and any group of cameras CAM-G (camera group) [integer in the range 1-999999]; in this mode, only the MULT, OK keys and the rotations of the joystick axes will work.

      To select these parameters, enter a number on the device keypad, then press the corresponding key (MON/WIN/CAM/CAM-G).

      If the the server IP address and/or port is not accessible from the PTZ control device, the "Connect failed" message will be displayed on the control device screen after pressing the MON/WIN/CAM/CAM-G keys.


The Hikvision DS-1200KI PTZ control device is now preconfigured.

Features of the Hikvision DS-1200KI control device operation in C-Werk

When the MULT, PRESET, PATROL, or PATTERN keys are pressed on the device, the following actions are performed: