You can run C-Werk installation in quiet mode (unattended setup with no user intervention).
During installation you may have to reboot the system. After rebooting the installation will continue automatically. |
When Redist.exe process ends and not listed in Windows Task Manager, the installation is complete.
This mode of installation can be configured by adding command-line options to setup.exe. See the command-line options in the table.
Command-line option | Description |
| /? or /help | Open the Help window |
| /x or /uninstall | Remove C-Werk and save the configuration |
| /x/removeall | Remove C-Werk and delete the configuration |
| /r or /repair | Repair C-Werk |
| /qn or /quiet | Silent install |
| /norestart | Disable automatic reboot of the system during installation |
| /debug | Log installation |
| /noOSCheck | Skip OS compatibility check |
| /postgresinstalldir="D:\Postgres" | PostgreSQL installation folder |
| /LANG=”en” | Select installation language: For example, en — English |
| /INSTALLTYPE="ServerClient" | Installation options:
|
| /ADD="[]" | Hers is the list of components to install or remove (if you remove/uninstall software). See the possible values in the table below. |
| /REMOVE="[]" | Hers is the list of components NOT to install or remove (if you remove/uninstall software). See the possible values in the table below. |
| /dpcmd="INSTALL_BOSCH_VIDEOSDK=\"no\"" | Bosch VideoSDK driver Installation (see notes).
|
| /CMD="[commands]" | Basic installation options and values. Commands are [option] = \ "[value] \" or [option] = [value]" . See available installation options in the table below. |
Occasionally, when installing the Bosch VideoSDK driver, the CLI window opens. To continue with installation, close this window. |
/ADD and /REMOVE values:
x64 |
| Acrobat |
| BaseProduct |
| IPDriverPack_x86 |
| Guardant_amd64 |
| Postgres |
| dotnetfx35_x86 |
| Redist2005_x86 |
| Redist2010_x86 |
| DetectorPack |
Installation options:
Installation options | Description |
| QUICKLAUNCH_SHORTCUT='1' | Create shortcut:
|
| DESKTOP_SHORTCUT='1' | Copy shortcut to desktop:
|
| INSTALLDIR='[%ProgramFiles%\Grundig\C-Werk]' | C-Werk installation folder |
| NGP_IFACE_WHITELIST="0.0.0.0/0" | Network interfaces The default value is "0.0.0.0/0" (all available network interfaces) Format of network interfaces: "IP-address1 / number of unit bits in the mask, IP-address2 /number of unit bits in the mask" |
| NGP_ALT_ADDR="0.0.0.0" | Setting the outside local address for a Server behind the NAT). Format of network interfaces: "IP Address1 or DNS-name1, IP address2 or DNS Name2" |
| PORT_RANGE_START="20111" | The initial value of the port range for Server. 20111 — default. |
| PORT_RANGE_COUNT="100" | Number of ports in use. The minimum number is 20. 100 — default. |
Options for Server and Client installation | |
| PATH_TO_DATA = 'X:\C-WerkData', where X is the letter of the disk with the most free memory | Directory for storing the log database and metadata database. Default is X:\C-WerkData. The PATH_TO_DATA parameter should be after the INSTALLDIR parameter. |
| FBUSER_TYPE='DEFAULT' | User account for file explorer:
|
| FBUSER_NAME='[C-Werk File Browser]' | Setting a user name and password for an account in file explorer. When you choose SPECIFY of the FBUSER_TYPE parameter |
| FBUSER_PSW='[Axxon2.0.0]' | |
| CONFIG_PATH='[CommonAppDataDirectory]' | Path to configurations files and folders |
| DOMAIN_NAME_TYPE = '[NewDomain]' | Select Domain:
|
| WHATDBUSE = '[EXIST]' |
|
| WHATVMDADBUSE = '[EXIST]' |
|
The command for silent installation of C-Werk may look like:
setup.exe /quiet /norestart /debug /INSTALLTYPE="ServerClient" /REMOVE="Guardant_amd64" /CMD="CREATE_QUICKLAUNCH_SHORTCUT=\"0\" PORT_RANGE_COUNT=\"50\" DOMAIN_NAME_TYPE=\"WithoutDomain\""
This will launch installation with the following options: